Dear Customer
The problem of ENW-9504 is on the NETRTS.INF
file of win95b_98 directory.
This file refer to wrong .sys file. click here
for the correct INF file .
If the user had tried to install the wrong
file and then try to install the correct file,
he will meet problem since win98 have loaded the
wrong .INF file. To solve this problem,
please ask the user to go to "windows\inf\other"
directory of his computer and find a file called
netrts.inf. Remove this file and restart
the computer. The user will then be
able to install the correct .INF files.
Please note the driver on win95b_98 directory is
NDIS3 driver.
If the OS is win98 second edition, we suggest to
use the NDIS5 driver on "win98_me" directory.
Sorry for the inconvenience.
If you have any further questions, please feel
free to contact us.